38 kg cm2 of boiler

Boiler water Limit:- - Altret

Feed Water & Boiler water Characteristics as per IS:10392-1982 1.FEED WATER Parameters Upto 20 Kg/cm2 21 Kg/cm2 to 39 Kg/cm2 40 Kg/cm2 to 59 Kg/cm2 Unit Total Hardness <10 <1.0 <0.5 ppm as CaCO 3 pH Value 8.5-9.5 8.5-9.5 8.5-9.5 Dissolved Oxygen 0.1 0.02 0.01 As ppm Silica 5 0.5 As ppm SiO 2

Get a Quote

the pressure of boiler is 9 5 kg cm2

38 Kg Cm2 Of Boiler - pension-hotel-jena.de. Boilers and Pressure Parts OPTI Engineering. Systems & Certifications Quality Management System ISO 9001:2008 certified. IBR Approval for Package Boiler up 10.5 Kg/cm2 Design Pressure and 4000 Kg/hr Steaming Capacity and Boiler Pressure Parts including HRSG modules and All types of Coils

Get a Quote

Appendix A: Boiler Calculations | Газогенераторы МСД

For the second SVLP, usually there is a stepping of a minimum of 0.34 bar, 0.35 kg/cm2, or 5 psig. Boiler design pressure is the highest SVLP, which is usually the second SVLP unless the boiler demands more SVs.

Get a Quote

How to convert steam pressure (Kg/cm2) into steam flowrate

This 3.0 Kg/cm2 steam is distributed into entire plant. The reactor I am talking about is 600 m away from the boiler and receives steam of 1.5 Kg/cm2 may be due to pressure drop along the line.

Get a Quote

Boiler Presentation - SlideShare

Jun 21, 2012 · Boiler Presentation 1. By- Mukesh Jha Sr.Engineer -Projects,a2z Powercom Pvt.Ltd. 2. Boiler-As per THE INDIAN BOILERS(AMENDMENT ) ACT2007A Boiler means a pressure vessel in which steam is generatedfor use external to itself by application of heat which is whollyor partly under pressure when steam is shut off but does notinclude a pressure vessel(1) With Capacity less than 25 ltrs

Get a Quote

58 kg cm2 steam boiler - gadfas.org.uk

boiler (engineering design guideline) - MAFIADOC.COM. Fired tube boilers typically have a lower initial cost, are more fuel efficient and are easier to operate, but they are limited generally to capacities of 25000 kg/h and pressures of 17.5 kg/cm2 b. Water Tube Boiler Water is flowing inside the tubes.

Get a Quote

200+ TOP Steam Boilers, Engines, Nozzles and Turbines MCQs Pdf

Steam Boilers, Engines, Nozzles and Turbines Questions :- 1. For water, at pressures below atmospheric, (a) melting point rises slightly and boiling point dro Steam Boilers, Engines, Nozzles and Turbines Questions and Answers pdf free download for freshers and experienced mechanical engineering students.Mcqs

Get a Quote

HOW TO DO BOILER ALKALI BOIL OUT DURING BOILER COMMISSIONING

Oct 17, 2016 · -After the completion of 12 hours of boil out operation, the boiler is boxed up and allowed to cool naturally, so that the pressure is dropped to 1 kg/cm2. At 1 kg/cm2 . pressure, the boiler is drained through low point drains.The super heaters are back flushed thoroughly.

Get a Quote

Boiler Hydrostatic testing procedure - Boilersinfo

Once the Boiler pressure is raised to 10 kg/ cm2 (g) stop the pump and observe the pressure drop. Boiler Hydrostatic testing pressure gauge If no leakage is observed to the satisfaction of the inspecting personnel, start the pressurizing pump.

Get a Quote

harga boiler 42 9 kg cm2 - culinarium-marburg.de

38 Kg Cm2 Of Boiler - despeelkamer.be. 25 TPH, 50 Kg/cm2 Rice Husk Fired Steam Boiler - YouTube. 3/12/2014· Erection Stage Video of 25 TPH, 50 Kg/cm2 Oil fired Steam Boiler Retrofitted to 25 TPH, 50 Kg/cm2 and 440 Deg C on Rice Husk in 2006 at One of the leading Ri: Goswami Naveen: 12K: 3 CHAPTER TWO: Boiler Operation Maintenance & Safety

Get a Quote

F & A Rating Of Boiler - Student - Cheresources.com Community

Mar 14, 2008 · F & A Rating Of Boiler - posted in Student: we need to calculate the boiler capacity based on F&A rating.Our consumption is 2500 kg/hr steam at 17kg/cm2(g)We provide feed water at 100degC to the boiler drum.please suggest, how to arrive at F&A rating.Thanks in Advance.Regards,raghav.

Get a Quote

BOILERS | Energy-Models.com

IBR Steam Pipe means any pipe through which steam passes from a boiler to a prime mover or other user or both, if pressure at which steam passes through such pipes exceeds 3.5 kg/cm 2 above atmospheric pressure or such pipe exceeds 254 mm in internal diameter and includes in either case any connected fitting of a steam pipe.

Get a Quote

Construction of 500 MW Steam Boiler - SlideShare

Jan 15, 2014 · According to working pressure Sub critical pressure boiler : when working pressure of boiler is between 130 to 180 kg/ cm2 critical boiler : when working pressure of boiler is 225.56 kg/ cm2 Super critical boiler : when working pressure of boiler is 240.10 kg/ cm2 7.

Get a Quote

BOILERS | Energy-Models.com

IBR Steam Pipe means any pipe through which steam passes from a boiler to a prime mover or other user or both, if pressure at which steam passes through such pipes exceeds 3.5 kg/cm 2 above atmospheric pressure or such pipe exceeds 254 mm in internal diameter and includes in either case any connected fitting of a steam pipe.

Get a Quote

1.5 MW Ape Belliss Steam Turbine & 15 T.P.H. Thermax Boiler

Distributor / Channel Partner of 1.5 MW Ape Belliss Steam Turbine, 15 T.P.H. Thermax Boiler, 50 TPH Boiler, 750 Kva Back Pressure Steam Turbine and 600 HP APE Belliss Steam Turbine offered by Deal 2 Machines, Ghaziabad, Uttar Pradesh.

Get a Quote

RELATED BOILER INFORMATION